Copy this text
Acoustic signal, data from the EGIM, EMSO-Azores observatory, 2017-2018
This dataset contains acoustic signal acquired between July 2017 and August 2018 on EMSO-Azores observatory by the EGIM. Acoustic signal is one of the 7 core parameters monitored by the EGIM, EMSO Generic Instrumental Module.
The EGIM prototype was deployed at Lucky Strike hydrothermal vent site, 25 m south west of the active edifice Tour Eiffel, to monitor local hydrodynamic variability and complement the data obtained by the numerous sensors set on this site: oceanographic mooring deployed south of the vent field, the multidisciplinary Seamon East node, autonomous current meters, array of temperature probes…
Disciplines
Physical oceanography
Keywords
Mid-Atlantic Ridge, EMSO-Azores, Lucky Strike, Acoustic, Hydrophone, EGIM, Time-series, MoMAR, MoMARSAT2018, EMSOdev, EMSO
Location
37.30134N, 37.2888S, -32.275618E, -32.27982W
Devices
Parameters
- Acoustic signal (audio .wav files)
Location
- Regional node: Emso-Azores
- Site: Lucky Strike
- Node: EGIM
- Coordinates: N37° 17' 19.61'' and W32° 16' 33.06''
- Depth: 1700 m
Installation
- Cruise: SARRADIN Pierre-Marie, CANNAT Mathilde (2017) MOMARSAT2017 cruise, RV Pourquoi pas ?, http://dx.doi.org/10.17600/17000500
- Dive: N°673-7 on July the 20th
Recovery
- Cruise: CANNAT Mathilde, LEGRAND Julien MOMARSAT2018 cruise, Atalante, http://dx.doi.org/10.17600/17000500
- Dive: N°696-1, August 2018 the 12th
Operating parameters
- Measurement duration: 90 days
- Sampling period: continuous recording, 1 .wav file/hour
- Anti-fouling device: No
Sensor metadata
- Type: Hydrophone
- Provider: Oceansonics
- Model: icListen HF
- Serial number: 1636
- Firmware release : 31.2
- Hardware release : 4
Sensor configuration
- Waveform frequency : 3200Hz (8kS/s)
- Sensitivity : -170.7dBV re µPa
Test and calibration
- Manufacturer calibration (2016)
Data management
- Real time data transmission: No
- Data storage in the Communication and storage unit (COSTOF2): No
- Data storage in the instrument: Full